1RB1LA_1LC1RD_1LA0LC_1RE0RB_1RB0RF_0RB---
1RB1LA_1LC1RD_1LA0LC_1RE0RB_1RB0RF_0RB--- (bbch) is a BB(6) holdout. It appears in the 608-machine BB(6) holdout list of 30 October 2026[1] and is classified as a shift overflow counter in the annotated holdout spreadsheet, with no further notes there.[2]
The holdout 1RB1LA_1LC1RD_1LA0LC_1RE0RB_1RB0RF_1RC--- (bbch) (entry 114206) differs only in the F0 transition. In simulation up to steps, both machines reached new rightmost cells at exactly the same steps, so the observations below apply to both in that range.
Observed behavior
The observations below come from direct simulation up to steps by Parksumin1017 (with AI assistance). They describe the behavior seen in that range and are not a proof.
The only halting transition is F1. State F was entered 9 times in that range (at steps 8, 119, 1,385, 1,450, 4,072,066, 4,072,131, 8,593,883,023, 8,593,883,137 and 8,593,883,321), each time reading a 0. These entries happen only during resets.
Configurations are recorded at the start of each burst of tape growth to the right (the first new rightmost cell after more than 2,000 steps without one). The machine is in state D at all of these points. The tape is written from the leftmost visited cell up to the head, with run-length notation (1^n means n consecutive 1s, (10)^m means m copies of 10).
Counter phase
Shortly after the first reset (from step 4,302,471) the machine follows this rule exactly:
P(m, n, K) = 1^2 0 (10)^m 1^3 0 (10)^n T 1^K 0 T = 1^3 0 1^5 0 1 0 1^7 0 1 0 1^5 0 P(m, n, K) -> P(m-1, n+1, K+3)
Reaching P(m, n, K) takes exactly steps from the previous burst. This held for all 14 bursts from P(13, 0, 40) at step 4,302,471 to P(0, 13, 79) at step 2,151,523,936. At every one of them m + n = 13 and K = 40 + 3n.
The next burst, steps later at step 4,299,007,581, shows
1^4 0 (10)^14 T 1^82 0
Resets
The first reset happens near step . The last burst before it (step 2,098,539) and the first burst after it (step 4,073,104) show
1^4 0 (10)^3 1^9 0 1 0 1 0 1^5 0 1^5 0 1 0 1^49 0 1^2 0 (10)^15 1^9 0 1 0 1^7 0 1 0 1^5 0 1^31 0
The second reset happens near step . The first burst after it (step 8,593,883,364) shows
1^2 0 (10)^25 1^5 0 1^3 0 1 0 1^3 0 1^7 0 1 0 1^3 0 1^15 0 1^5 0 1^4 0 1^37 0
After the second reset, the middle of the tape changes like a further counter from burst to burst, and the rule above no longer applies. The gaps between bursts still roughly double, reaching 536,870,937 steps by step 9,667,887,252. The exact rule for the resets and for this later phase has not been derived here.
Automated tools
Quick_Sim.py from sligocki/busy-beaver (commit 192fb41, default prover level) proved no rules for this machine. It was run with the automatically chosen block size (2) for about 4.5 minutes, and with block sizes 1, 3, 4, 5, 6 and 8 for 45 seconds each.
References
- ↑ BB6_holdouts_608.txt (entry 53104)
- ↑ Annotated BB(6) holdout spreadsheet